Add to Cart
FA-IOC-BOC48 , 48 Cores Fan-out Type Indoor Optical Fiber Cable With 4 Sub Units And Rip Rope
The branch indoor fiber optic cable can be mainly divided into two kinds, the first is flat ribbon branch cable composed of many parallel branch cable, the second is an integrated round branch optical fiber cable. The size of optical fiber cable is related to the number of sub optical fiber cable, the requirements of sub optical fiber cable and the form of branch optical cable.
The tensile properties of optical fiber cables are closely related to the number of sub cables. That is to say, the number of sub optical cables is different, the tensile properties of the cables are different. Crushing resistance of the branch cable meets or exceeds common fiber cable. High and low temperature and water permeability can meet the requirements of ordinary fiber optic cable.
The branch optical cable has good advantage in practical application. First, the branch fiber optic cable can be separated to sub optical fiber cable in different qty according to indeed of network point; Second, cross section of the branch optical cable can easily be divided into sub fiber optic cable. Third, the cable joint does not require to cut the whole cable so it can reduce joint point and easy for operation. Since the number of optical cable connections is reduced, the failure rate of optical cable is greatly reduced, and the reliability of optical cable lines is improved.
For the FTTH network, the network density is the biggest, no matter outdoor cable to the community, to the building, or indoor cable FTTH, fiber to the desktop,density of the branch cable can be imagined,branch cable is more superior in the network application, it can reduce a large number of cable joint, thereby greatly reducing the fault point by cable, effectively improve the reliability of the network.
Characteristic
1, With excellent mechanical and environmental performance;
2, Suitable for dense indoor cabling;
3, Flexible, soft and easy for bending and operation;
4, Various fiber type and jacket material for option;
5, With many sub unit with fan-out cable inside, do not need to cut the whole cable in joint point.
Cable Parameters Of FA-IOC-BOC48
Fiber Capacity | Sub Units | Fiber in unit | Outer Diameter | Weight (KG/KM) |
24 | 2 | 12 | 19.0 | 210 |
36 | 3 | 12 | 20.0 | 210 |
48 | 4 | 12 | 20.0 | 250 |
72 | 6 | 12 | 21.0 | 300 |
96 | 8 | 12 | 25.5 | 460 |
144 | 12 | 12 | 28.2 | 680 |
Temperature range | ℃ | -20~+60 | ||
Minimum Bending Radius | Static | mm | 10D | |
Dynamic | mm | 20D | ||
Maximum Tensile Strength | Short term | N | 1300 | |
Long term | N | 400 | ||
Maximum Crush Resistance | N/100mm2 | 1000 |